News

23/01/2011

A clear head and wellbeing

Frequent headaches, anxiety and stress.

CEFALY can change your life. With its pleasant

stimulative effect, it inhibits pain, arrests

headaches, calms anxiety and soothes stress.

A few sessions a week are all that’s needed

to restore your wellbeing, clear your head and

alleviate stress.

 

Indications

• Anterior tension headaches

• Migraines with or without aura

• Treatment of stress and anxiety

• Cluster headache

• Ophthalmic shingles

• Frontal sinusitis (symptomatic treatment)

• Trigeminal neuralgia affecting the first branch of the trigeminal nerve (Willis ophthalmic nerve).

 

Very recently external cranial neurostimulation has been developed. The technical progresses consist in having a practical and comfortable device. Before the technique wasn’t used because it was painful and complicate. STX-Med has made significant progresses in electronic and devices simple to use. The first device available is intended for supra orbital neurostimulation and so-called CEFALY® The company is currently doing researches about devices for other location of neurostimulation as occipital and neck. Therefore Cefaly technique is external neurostimulation but very similar to implanted neurostimulators: similar electrical parameters leading to same basic action of triggering action potentials on nerves at same frequency.

15/10/2010

Ultragel 2000 Ltd, is kindly informing  its partners that also in year 2010, we are participating in MEDICA Exhibition, Düsseldorf, 17-20 November, on  the world’s largest medical trade fair.

We are welcoming all our current or future hungarian and foreign partners on our stand E45, in hall 9.

Looking forward to meeting You!

(During the exhibition period there won’t be any intermission in online ordering and purchasing)

Medica 2010

Most popular products

Forum

No Topic!

Visitor counter

1
2
5
9
1
6
4

Más dimenzióban az egészségügyben

Kérdése van? Hívjon minket! +36 30 228 03 52

Easy Reader Plus rapid immunochromatography laboratory

Easy Reader Plus rapid immunochromatography laboratory
Easy Reader Plus rapid immunochromatography laboratory
Easy Reader Plus rapid immunochromatography laboratory
Easy Reader Plus rapid immunochromatography laboratory
Easy Reader Plus rapid immunochromatography laboratory
Easy Reader Plus rapid immunochromatography laboratory
Easy Reader Plus rapid immunochromatography laboratory

Easy Reader Plusz - VEDA LAB test cassette quick wine device

 

The EasyReader+ instrument is a lateral flow immunochromatographic analyser for quantitative results.

The EasyReader+ installation kit includes the analyser and software that allows the operator to perform the evaluation, control the operation, store the measurement results and move them to the database.

 

Operating principle:

EasyReader+ uses lateral flow immunochromatographic test technology
The EasyCheck® system uses direct immunoassay technology with nitrocellulose membrane rapid test devices.


Rapid test device technology
The sample to be tested (as described for each parameter on the device
type of sample to be used) is loaded into the test devices by the operator. The sample is spontaneous,
spontaneously migrates across the nitrocellulose membrane by capillary action and the membrane is
particles and molecules present in different parts of the membrane.
1 First it interacts with the conjugate; the particles attach to the coloured or
coated bioactive particles. The sample particles passing through the conjugate are thus also
coated with colour.
2 The test sample passes through the Test Line (T) and the Control Line (C),
where the membrane contains two types of identification molecules:
- in the control strip, the molecules bind all particles passing through the strip and this
indicates that the test device is working. If a sufficient amount of coloured coating is applied
test sample particles bind, a coloured band will appear on the control strip; this indicates that the test sample is
indicates that the test result is valid.

 

Depending on the presence of the analyte in the sample, the colour of the test strip will vary in intensity
This allows for the quantification of the analyte.

Measurement time / result: 0 - 15 min

 

Available qualitative tests:

Adenovirus, BNP, C.d. Toxin A, C.d. Toxin B, C.d. GDH, C.d. C.D.D. Toxin A+B, hCG (10 min), hCG (5 min), Influenza A, Influenza B, Combo Influenza A+B, Legionella, Rotavirus, Combo Rotavirus+Adenovirus, RSV, Strep. A, Strep. pneumoniae, Tetanos, Tuberculosis

 

Available quantitative tests:

AFP, CA-125, CA 15-3, CA 19-9, Calprotectin, CEA, CK-MB, Cortisol, Covid-19 Spike IgM/IgG, C-peptide, CRP (laboratory or doctor's office), HS-CRP (laboratory or doctor's office), Cystatin C, D-Dimer, FABP, Ferritin, FOB, FSH, HbA1c, Hb-Total, hCG, beta-hCG, IgE, Insulin, HS-Insulin, LH, Microalbumin, Myoglobin, NT-proBNP, Procalcitonin, Prolactin, HS-Prolactin, PSA (quantitative or semi-quantitative), PSA Free, Total T3, Total T4, Transferrin, Troponin I, TSH, HS-TSH, ULTRA-TSH

 

Available veterinary quantitative tests:

Cortisol, CRP Canine, Progesterone Canine, SAA, Total Hb, Total T4, TSH canine

 

Details
1 430 000 Ft
Details

Babycheck-1 Duo (hCG dual test 5 mlU/ml & 1000 mlU/ml at 10 min – visual qualitative read only)


EasyReader+ test tool processing

1, After the test sample has been measured on the test device, device-specific incubation
time must elapse before reading. You can measure the incubation time yourself, but you can also set the
EasyReader+ to count down.
2 When the incubation time has elapsed, the device LED will illuminate the test device
nitrocellulose membrane of the test device.

The green light is used for evaluation and to help detect potential discoloration
contrast of potential staining by providing an effective highlight against the white background of the image.
3 A CMOS camera takes a picture of the device's oval test block under the LED light
by the light of the LED. The image processing software scans the image, detects the discoloration and
calculates the average saturation of the colour area on the membrane.
4 The microprocessor calculates the average saturation value detected in the image using the preset
device specific cut-off value range and thus provides a semi-quantitative
test result.

 

 

Limitations of use:
Reactivity detected by rapid test devices can be compared with other test methods and
clinical results.
- The results obtained with rapid test devices should be confirmed by diagnostic procedures and clinical
results should be evaluated in conjunction with clinical and clinical results.
- A negative result in a given patient indicates that the level of the marker being tested is not
detectable. A negative test result does not exclude the possibility that the marker
one or more diseases associated with the marker.

 

 

Technical specifications

Type Reflectance photometer
Dimensions

Weight: 1500 g
Height: 170 mm
Width: 150 mm
Depth: 180 mm
Capacity Normal incubation mode: approx. 5 samples/hour
External incubation (instant) mode: approx. 50 samples/hour
Power supply External adapter: 100-240 V AC, 50-60 Hz, with 7.,5 V DC output;
optionally from battery: 6 AA batteries/NiMH battery


Operating conditions:
Temperature: +15°C to +40°C

 

Printer parameters

Thermal paper printer
Maximum roll width: 60 mm


Database capacity 1000 measurements
Screen Size: 4.3"
Resolution: 480× 272 pixels


Connectors

Internet, PS2 port, Serial RS232, USB A Type A, USB B Type

 

Babycheck-1 Duo (hCG dual test 5 mlU/ml & 1000 mlU/ml at 10 min – visual qualitative read only)

Info
Article No.
UG745895
Weight
1.5 kg/pcs
Opinions

Be the first to review this product!