Adult or child mode, selectable energy levels ( 4 levels)
Three-step resuscitation process
Colour display
Volume adjustable in 5 steps
Daily, weekly and monthly self-test
Two button operation - to select child and adult mode
Extensive audio and visual instructions on colour display
Two-phase power output
Protection against accidental defibrillation
The device has an internal memory (60 hours)
ECG signals and events can be transferred to the computer via an infrared port
Defi5S AED with carrying case
Has a carrying handle for easy transport
Long-life non-rechargeable 3000mAh LiMnO2 type battery. Battery life of at least 5 years.
Display ekg signals before firing the shock
AED software (option) that supports transmission of storage data, documentation of events, real-time ECG display, waveform display of voice commands, display of voice commands and printing of selected waveforms

Technical parameters:
Dimensions 303 x 216 x 89 mm
Weight 2,0 kg
Defibrillation:
Child mode: 30, 30, 50 joules
50, 50, 75 joules
Adult mode: 120, 120, 150 joules
150, 150, 200 joules
150, 150, 200 J
Charging: less than 6 seconds up to 150 Joules and 8 seconds up to 200 Joules
Impedance range: 20Ω to 200Ω
22 beeps, LED messages
Two buttons OFF/OFF; SOKK


1. Data communication
The AED storage software supports the AED in receiving data sent via an infrared link. Meditech AED storage software supports setting and reading ECG waveforms, setting the language of the AED, and reading and analyzing data. Data can also be deleted using the Meditech AED storage software.
2. Case management
Meditech AED storage software manages data files as case files and stores cases in the ACCESS database. Case management supports importing and deleting data that responds to ECG wave files.
3. Memory Replay
The interface displays data recorded during AED operation, such as type, event time, description, waves. Event types include self-test, self-start event, energy charge, energy discharge, CPR start and stop, and general display of patient status. "OHM" indicates the resistance that has been applied to the patient. The current parameters are displayed during the event. "Shock required" indicates if shock is recommended, while "No shock required" indicates if shock is not recommended.
4. ECG
ECG waveform amplification can be set to 5mm/mV, 10mm/mV or 20mm/mV. The waveform speed can be 12.5mm/s, 25mm/s, 50mm/s.
5. Printing
The print page can be selected in the playback interface and used to print basic information.