News

23/01/2011

A clear head and wellbeing

Frequent headaches, anxiety and stress.

CEFALY can change your life. With its pleasant

stimulative effect, it inhibits pain, arrests

headaches, calms anxiety and soothes stress.

A few sessions a week are all that’s needed

to restore your wellbeing, clear your head and

alleviate stress.

 

Indications

• Anterior tension headaches

• Migraines with or without aura

• Treatment of stress and anxiety

• Cluster headache

• Ophthalmic shingles

• Frontal sinusitis (symptomatic treatment)

• Trigeminal neuralgia affecting the first branch of the trigeminal nerve (Willis ophthalmic nerve).

 

Very recently external cranial neurostimulation has been developed. The technical progresses consist in having a practical and comfortable device. Before the technique wasn’t used because it was painful and complicate. STX-Med has made significant progresses in electronic and devices simple to use. The first device available is intended for supra orbital neurostimulation and so-called CEFALY® The company is currently doing researches about devices for other location of neurostimulation as occipital and neck. Therefore Cefaly technique is external neurostimulation but very similar to implanted neurostimulators: similar electrical parameters leading to same basic action of triggering action potentials on nerves at same frequency.

15/10/2010

Ultragel 2000 Ltd, is kindly informing  its partners that also in year 2010, we are participating in MEDICA Exhibition, Düsseldorf, 17-20 November, on  the world’s largest medical trade fair.

We are welcoming all our current or future hungarian and foreign partners on our stand E45, in hall 9.

Looking forward to meeting You!

(During the exhibition period there won’t be any intermission in online ordering and purchasing)

Medica 2010

Most popular products

Forum

No Topic!

Visitor counter

1
2
7
0
3
4
6

Más dimenzióban az egészségügyben

Kérdése van? Hívjon minket! +36 30 228 03 52

Body composition analyser - Charder MA801

Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801
Body composition analyser - Charder MA801

Top of the rangeBody composition analyser - Charder MA801
Professional body composition analyser

Data storage of 100 000 tests

 

Capacity: 300 kg

 

Wifi, USB connection

 

Measurements
25 impedance measurements:
5 frequencies (5kHz, 20kHz, 50kHz, 100kHz, 250kHz)
5 body parts (right arm, left arm, torso, right leg, left leg)

 

Measured parameters:
Skeletal muscle mass, extracellular water (ECW), intracellular water (ICW), total body water (TBW), comparison of ECW/TBW parameters, body fat, body fat percentage (PBF), metabolic rate (basal metabolic rate, total energy expenditure), segmental lean mass, segmental fat mass, visceral fat area (VFA), visceral fat level, body type analysis, weight control, fat control, muscle control, body balance, health score, fat free mass segmental (FFM), fat mass index (FMI), fat free mass (FFMI), skeletal muscle index (SMI), appendicular skeletal muscle index (ASMI), adhesion strength, protein, minerals, soft lean mass, waist-to-hip ratio, waist circumference, body cell mass, arm circumference, arm muscle circumference, subcutaneous fat, bioelectrical impedance vector analysis (BIVA), waist height ratio, growth chart, growth history, assessment and recommendations

 

Results sheets
Medical, Normal, Child

 

Coaches and athletes know best that fitness is much more than how you look or how much you weigh! Quantifying how your muscles change. Examining whether weight loss is due to fat loss or, for example, insufficient water intake, can help you track where changes are happening, where you need to focus your efforts.

Charder is proud to introduce the MA801 Body Composition Analyser, designed to help professionals design and analyse quality programmes.

 

The MA801 Body Composition Analyzer provides the relevant metrics and data you need to take your program to the next level. Boasting multiple measurement frequencies and sophisticated algorithms, Charder stands behind its instruments with clinical trials and more than 10 years of peer-reviewed scientific research for reliable results.

 

cece-oimlce-m

Details
4 990 000 Ft
Details

A new generation of detailed measurements


Easy to use
Thanks to an intuitive touch screen interface and voice guidance during the measurement process, minimal training is required to operate Charder's professional instruments safely and correctly. Perform a specific test in less than a minute and get clinically validated results.

 

Non-invasive and safe bioelectrical impedance analysis
With Bioelectrical Impedance Analysis (BIA), our devices send a safe, alternating current through the body via the machine's touch points. Through advanced algorithms that analyze resistance to electrical current, we provide muscle, fat, water, cell health, metabolic and more performance!

 

Clinically validated results
It's not just how many results you get, it's whether you can trust them. Charder's years of research in bioelectrical impedance analysis includes the use of artificial neural networks, with algorithms that have been developed and validated against gold-standards such as computed tomography and dual X-ray absorptiometry for reproducible results.

 

What is body composition?
Simply put, body composition analysers analyse the body and divide it into its basic components of water, fat, protein and minerals. This provides a detailed and accurate weight breakdown and provides key insights that traditional methods such as BMI cannot.

 

Why is BMI not enough for professional use?
The Body Mass Index (BMI) is a commonly used method of assessing the health of an individual by comparing their weight and health status. The primary limitation of BMI is that it only uses total body weight and there is no way to determine whether weight changes are due to fat or muscle. Two people with the same BMI should be classified as having the same health risk, even if one is mostly fat and the other is mostly muscle!

 

Why is body composition measurement important?
Traditionally, many fitness or dietary goals have focused on weight gain or loss - understandable if you only have one scale. With bioelectrical impedance analysis (BIA), which makes body composition more accessible, safe and affordable than other analysis methods, you can regularly monitor key components of your body, giving you a valuable snapshot of your health!

 

What does our resistance show?
Generally speaking, water acts as a conductor, so more body water correlates with decreased Resistance. According to this principle, because muscle contains a significant amount of water, people with increased muscle mass will have lower resistance. Conversely, because fat acts as an insulator, more fat correlates with increased resistance.

What does Reactance show?
When an electric current passes through the cells of the body, the cell membranes can store the charge and act as capacitors, creating capacitive resistance. Thus reactance is used to determine the energy storage capacity of a cell, indirectly reflecting the integrity and strength of the cell.

Using clinically validated algorithms, BIA Body Composition Analyser tools can calculate the amount of fat, muscle, body water and other parameters using Impedance, Reactance, Resistance and other variables such as height, gender, age and weight. The applicability of a BIA tool depends essentially on the mathematical equations and algorithms used to calculate body composition. Developing and validating these equations is a technically complex process and the validity of the equations ultimately determines the accuracy of the BIA tool!

 

 

 


Test result in adults

 

 

Test result in children:

 

Child Result Sheet (Color) for MA601 & MA801 Body Composition Analyzers

Info
Article No.
UG770710