News

23/01/2011

A clear head and wellbeing

Frequent headaches, anxiety and stress.

CEFALY can change your life. With its pleasant

stimulative effect, it inhibits pain, arrests

headaches, calms anxiety and soothes stress.

A few sessions a week are all that’s needed

to restore your wellbeing, clear your head and

alleviate stress.

 

Indications

• Anterior tension headaches

• Migraines with or without aura

• Treatment of stress and anxiety

• Cluster headache

• Ophthalmic shingles

• Frontal sinusitis (symptomatic treatment)

• Trigeminal neuralgia affecting the first branch of the trigeminal nerve (Willis ophthalmic nerve).

 

Very recently external cranial neurostimulation has been developed. The technical progresses consist in having a practical and comfortable device. Before the technique wasn’t used because it was painful and complicate. STX-Med has made significant progresses in electronic and devices simple to use. The first device available is intended for supra orbital neurostimulation and so-called CEFALY® The company is currently doing researches about devices for other location of neurostimulation as occipital and neck. Therefore Cefaly technique is external neurostimulation but very similar to implanted neurostimulators: similar electrical parameters leading to same basic action of triggering action potentials on nerves at same frequency.

15/10/2010

Ultragel 2000 Ltd, is kindly informing  its partners that also in year 2010, we are participating in MEDICA Exhibition, Düsseldorf, 17-20 November, on  the world’s largest medical trade fair.

We are welcoming all our current or future hungarian and foreign partners on our stand E45, in hall 9.

Looking forward to meeting You!

(During the exhibition period there won’t be any intermission in online ordering and purchasing)

Medica 2010

Most popular products

Forum

No Topic!

Visitor counter

1
2
5
8
7
9
1

Más dimenzióban az egészségügyben

Kérdése van? Hívjon minket! +36 30 228 03 52

Steam Sterile Autoclave 18L - Sterix

Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix
Steam Sterile Autoclave 18L - Sterix

Autoclave 18L - Sterix

 

The STERIX 18, Class B autoclave with 18 litre stainless steel chamber.

The 26 cm chamber diameter allows for greater sterilization and better instrument positioning.

The Sterix table top autoclave is suitable for sterilising the most delicate surgical and reusable instruments. Thanks to its unique heating system, the instruments are not exposed to thermal shocks, thus maintaining their original operating characteristics.

 

6 reasons to choose Sterix:
Although the EN13060 standard seems to smooth out the differences, the technologies and materials used by different manufacturers allow them to offer very different performance Class B autoclaves with very different reliability, safety, ease of use and sustainability ratios. Sterix redefines sterilisation in the sector!

 

1, Superior performance
Speed: A fast machine can perform many more cycles in a day, allowing sterilisation of many more instruments.
A fast cycle of 20-30 minutes allows sterilisation of instruments between two patients.
Capacity: thanks to the enlarged sterilisation chamber (260 mm) and the Trays Modular System, Sterix can accommodate more trays (up to 7) and cassettes (up to 4), as well as organising mixed loads. .
All this allows (compared to other competitors) a 30-40% more favourable arrangement of more devices.
Gentle: the high performance vacuum pump can blow out all the air in a few minutes, allowing the vapour to settle on the most distant surfaces of hollow bodies and microstructures.
The special heating system prevents temperature changes that can damage the delicate micro-mechanisms of turbines and handpieces

 

2, Reliability
The innovative technologies used, the direct control of the entire manufacturing and testing process, and the choice of oversized quality components allow STERIX autoclaves to always operate below their limits without any loss of performance. The 2-year warranty on the autoclave and the 20 years/100 000 cycles on the chamber are concrete proof of reliability.
Reliability means higher yields and lower costs

 

3, User-friendly
Ease of use is not always obvious. The STERIX has a wide LCD touch panel that allows the operator to view all information and the operating status of the autoclave remotely. With just 4 touch buttons for navigation and parameter setting, it's easier and more intuitive. The use of the control panel reduces the possibility of malfunction or incorrect operation. Thanks to the IoT system, WI-FI connection is automatic, facilitating maintenance, service and validation operations. For STERIX, simplicity means fewer errors and less time!

 

4, Innovation and technology
STERIX perfectly combines experience and innovation: its heating system is equipped with a built-in double generator (Adaptive heat system), a heated ventilation system (Air warm up), a water preheater and a degassing system (Water warm up). New concept for the chamber weldless fixing, filter protected hydraulic circuit, internet connection system IoT with integrated WI FI, automatic operator detection system NFC etc.,

 

5, Safety
Safety above safety!
Given that the autoclave consists of a pressure vessel, it is important to eliminate all possible risks. Thanks to the elimination of structural welds and the use of a 4-hinge locking system, the risk of chamber failure is practically eliminated. With 2 or 3-hinge closures, the accidental failure of a hinge determines the sudden opening of the door. The 20-year guarantee for the room is proof of safety and reliability.

 

6, Eco sustainability
The balance between energy and electricity consumption and the possibility of sterilisation with "energy-saving" modes (night cycle, economy mode, etc.) allow consumption to be reduced without sacrificing performance. The use of stainless steel instead of plastic for the outer casing gives STERIX added value from an aesthetic, mechanical and environmental point of view.

3 340 000 Ft
Info
Article No.
UG686295
Weight
59 kg/pcs
Opinions

Be the first to review this product!

Additional products
Similar products