Most popular products

Forum

No Topic!

Visitor counter

1
3
1
7
4
5
3

Más dimenzióban az egészségügyben

Kérdése van? Hívjon minket! +36 30 228 03 52

Ten20 - outstanding conductivity and adhesion – in a 228g jar

Ten20 - outstanding conductivity and adhesion – in a 228g jar
Ten20 - outstanding conductivity and adhesion – in a 228g jar
Ten20 - outstanding conductivity and adhesion – in a 228g jar
Ten20 - outstanding conductivity and adhesion – in a 228g jar
Ten20 - outstanding conductivity and adhesion – in a 228g jar
Ten20 - outstanding conductivity and adhesion – in a 228g jar
Ten20 - outstanding conductivity and adhesion – in a 228g jar

Ten20 - outstanding signal transmission and adhesion - 228g jar

 

Ten20 provides the right balance between adhesion and conductivity, allowing electrodes to stay in place while enabling electrical signal transmission.

 

Electrodes stay in place

Ten20 conductive paste holds electrodes in place, so there is no need to interrupt the test to reposition the electrodes. This reliable paste conducts the signal that the industry relies on for clean results.

 

Professionals worldwide trust Ten20 paste for the optimum balance of adhesion and conductivity.

 

Apply your electrode with Ten20 and it will stay in place until it's removed!

 

 

Quick to clean

Ten20 is very easy to clean thanks to its washable, non-drying formula. To remove, simply wash it off with warm water; no harsh chemicals are needed.

 

Easy to use

Ten20 conductive paste is available in convenient 3-pack jars or tubes to meet all your needs. For patient safety, all products include an expiry date and a full list of ingredients.

 

Easy to store

All products are packaged in easy-to-store boxes that should be stored at room temperature. A three-year shelf life is indicated on the box and on each container.

Details
10 800 Ft
Details

Pastes and gels for EEG, ECG and sleep studies.

Electrode pastes and gels are used for skin preparation to reduce impedance when in contact with the skin, and as conductive and adhesive pastes for electrode attachment for routine EEG, long-term EEG, long-term video EEG, epilepsy EEG and sleep EEG/PSG testing.

 

 

Medical gels and pastes used for EEG, ECG, sleep diagnostics and EP studies serve three main purposes: preparing the skin, sticking the electrodes and conducting the signal.

 

 

1, Skin preparation

Dead skin cells, dirt, sweat and grease cause high transmission impedances, sometimes up to several megaohms (M Ω), between the skin and the electrode. Reducing this transfer impedance is essential for optimal measurement.

 

The AASM recommends an impedance below 5 kiloOhms (5 k Ω) and therefore the skin should be cleaned to achieve stable electrical contact and low transient impedance. A preparation gel such as Nuprep is used to clean the skin and achieve the optimal impedance. In case of very oily skin, alcohol wipes (e.g. isopropanol) can also be used to degrease the skin.

 

2, Conductivity and adhesion

To ensure stable and reliable conduction, electrodes (e.g. Gold Cup electrodes) should be fixed after skin cleansing. For this purpose adhesive/conductive pastes or gels (e.g. Lic2 , EC2 and Ten20) are used. These are of different thicknesses and are applied depending on the type of study (routine or long term lead) and the electrode (gold, Ag/AgCl cup electrodes or EEG system caps).

 

3, Pastes and gels for skin preparation

By default, Nuprep is recommended for skin preparation. The gel is also recommended for sensitive skin, as no skin irritation occurs during application. Nuprep does not contain latex, either as an ingredient or in the packaging. In addition, latex-free gloves are used in the manufacturing process to eliminate contamination. Nuprep is used to clean the skin, reduce impedance and improve conduction in the following tests:

 

EEG tests

Sleep diagnostics and sleep screening

Long-term ECG and short-term ECG

Evoked potential (EP) testing

Cardiac catheter monitoring

ECG telemetry

Cardiac stress testing

Cardiac rehabilitation monitoring

Intraoperative monitoring

Other skin preparation gels, such as Everi and Skin-Pure, are also used in EEG, EMG, EP, ECG and sleep studies.

 

Glue and conductive paste for EEG testing and sleep diagnostics

 

Adhesive and conductive pastes are used to fix electrodes (e.g. gold cup electrodes, silver-silver chloride cup electrodes (Ag/AgCl cup electrodes) or silver cup electrodes) during routine and long-term leads:

Electroencephalogram (EEG)

Electroneurography (ENG)

Brain mapping

Evoked potential (EP) testing

Neurofeedback

Sleep diagnostics and sleep screening (PG and PSG)

Multiple sleep latency test (MSLT)

 

Ingredients:

Polyoxyethylene 20 Cetyl Ether, Water, Glycerol, Calcium Carbonate, 1,2-propanediol, Potassium Chloride, Gelwhite, Sodium Chloride, Polyoxyethylene 20 Sorbitol, Methylparaben, Propylparaben.

Info
Article No.
UG373713
Weight
1 kg/pieces
Minimum order quantity
3 pieces
Quantity options
3 pieces, 6 pieces, 9 pieces, 12 pieces, ...
Opinions

Be the first to review this product!

Additional products
Similar products