Features:
- Hungarian language software, messages, menu
- Mobile, battery-powered ECG device
- Digital data acquisition
- Colour, graphic display.
- 10.1", touch screen control with patient data, settings and messages.
- Simultaneous display of 12 leads, heart rate display
- Battery capacity: 200 ECG recordings
- Data recording: simultaneous recording of 12 channels
- Patient data input from full character alphanumeric virtual keypad or transfer from PACS system.
- Print 12 channels per channel on built-in thermal recorder
- Print image configurable
- Paper speed: 5, 10, 25 or 50 mm/sec
- Manual and automatic recording
- ECG measurement: QRS distance, time, amplitude, tending data, average RR, QTcB, QTcF - numerically specified
- Veritas™ ECG scoring algorithm with gender and age specificity.
- The device not only gives an opinion on the recording, but also lists the possible causes of the ECG deviation.
- Automatic electrode impedance determination
- Conduction drop monitoring, defective electrode indication
- Warning in case of reversed lead, continuous ECG curve required for approx. 3 seconds
- Baseline wander correction
- AC mains noise filtering algorithm (50/60Hz)
- Muscle movement (tremor, tremor) filter algorithm*
- Defibrillator protection
- Memory for storage of 40 ECGs
- stored recordings can be recalled on the display of the device and can be printed and viewed again
- ECGs are automatically saved.
- If the memory is not read out, the oldest recording in memory is deleted to record the current recording.
- Save ECG to USB memory in pdf. format
- PC software is required to display recordings saved to USB memory and is included in the price
- Pacemaker spike detection with outstanding sampling rate of 40 000Hz/channel/sec
- Exceeds ACC, AHA, HRS, IHE, and European Cardiac Standards recommended data acquisition frequency response range (0.05-250 Hz) for paediatric use
- The Veritas interpretation algorithm supports the diagnosis of sudden cardiac death in athletes by measurement or automatic evaluation according to Seattle criteria:
o Automatic detection and assignment of QRS left axis deviation
o QTc, QTcF, QTcB calculations
o automatic detection and calculation of long QT interval
o automatic detection and display of abnormal T wave
o automatic recognition and output of ECG waveforms according to Brugada syndrome
o automatic detection and output of ST depression
o Automatic detection and writing of Left Tawara Stem Block (LBBB)
o automatic detection and recording of inter-ventricular conduction delay
o automatic detection and detection of left atrial enlargement
o automatic detection and detection of right ventricular thickening (LVH)
o automatic detection and detection of ventricular preexcitation
o automatic detection and triggering of rhythm events: sinus bradycardia, ventricular fibrillation, ventricular flutter, supraventricular rhythm event