News

23/01/2011

A clear head and wellbeing

Frequent headaches, anxiety and stress.

CEFALY can change your life. With its pleasant

stimulative effect, it inhibits pain, arrests

headaches, calms anxiety and soothes stress.

A few sessions a week are all that’s needed

to restore your wellbeing, clear your head and

alleviate stress.

 

Indications

• Anterior tension headaches

• Migraines with or without aura

• Treatment of stress and anxiety

• Cluster headache

• Ophthalmic shingles

• Frontal sinusitis (symptomatic treatment)

• Trigeminal neuralgia affecting the first branch of the trigeminal nerve (Willis ophthalmic nerve).

 

Very recently external cranial neurostimulation has been developed. The technical progresses consist in having a practical and comfortable device. Before the technique wasn’t used because it was painful and complicate. STX-Med has made significant progresses in electronic and devices simple to use. The first device available is intended for supra orbital neurostimulation and so-called CEFALY® The company is currently doing researches about devices for other location of neurostimulation as occipital and neck. Therefore Cefaly technique is external neurostimulation but very similar to implanted neurostimulators: similar electrical parameters leading to same basic action of triggering action potentials on nerves at same frequency.

15/10/2010

Ultragel 2000 Ltd, is kindly informing  its partners that also in year 2010, we are participating in MEDICA Exhibition, Düsseldorf, 17-20 November, on  the world’s largest medical trade fair.

We are welcoming all our current or future hungarian and foreign partners on our stand E45, in hall 9.

Looking forward to meeting You!

(During the exhibition period there won’t be any intermission in online ordering and purchasing)

Medica 2010

Most popular products

Forum

No Topic!

Visitor counter

1
1
6
4
0
3
6

Más dimenzióban az egészségügyben

Kérdése van? Hívjon minket! +36 30 228 03 52

Radio Frequency / Tecar Cream - RF Premium - 1kg

Radio Frequency / Tecar Cream - RF Premium - 1kg
Radio Frequency / Tecar Cream - RF Premium - 1kg

Radio Frequency RF / TECAR Cream

The use of the cream during radiofrequency / TECAR therapeutic (diathermy) treatments allows the reduction of contact impedance between the electrode and the skin. The high conductivity ensures the best results in both the capacitive and resistive phases of TECAR treatment.

The RF cream should be dispensed from the 1kg screw-top bottle using a spatula and applied to the treatment head/skin area. It is a white coloured, thick consistency, slightly scented, skin friendly product which, in addition to being effective in the treatment, also gently nourishes the skin. After use, wipe it off with a paper towel and disinfect the surface/skin to avoid cross-contamination of your patients.

The product was developed with a high viscosity as a primary consideration to avoid excessive heat sensation during prolonged treatments and high energy transfer.

It is particularly recommended for aesthetic treatments because of its high reabsorption and dense consistency, which contribute greatly to effective treatment.

Its unique consistency helps the electrodes to glide easily even on dry skin, making the practitioner's task easier and optimising results.

When used as a lubricant, it enhances the comfort and effectiveness of intimate treatments (e.g. intimate probes) and as an intimate moisturiser, it helps restore the natural firmness and elasticity of the mucosa.

It has been specifically developed to promote capacitive and resistive treatment of sensitive skin and sensitive areas of the body.

Details
10 800 Ft
Details

TECARTHERAPY Capenergy

The use of heat as a treatment for various conditions has been known for many years: it provides relief from chronic, traumatic and inflammatory conditions, increases blood flow by improving cellular nutrition and oxygenation, and speeds up the elimination of toxins; improves the elasticity of connective tissue, reduces joint stiffness, muscle pain and spasm, and promotes the absorption of haematomas and oedemas.

 

Use of tecarterapy:

The application of an electric field with the appropriate power, frequency and waveform characteristics to energise tissues, thus restoring chemical/electrical balance... This is the theory that justifies its use in physiotherapy. Each cell is involved in the regenerative function of tissue through morphological and chemical-electrical interactions.

The thermal action on an inflamed or damaged area frees up space before the mechanical action, allowing a longer treatment duration and deeper application.

 

Capacitive or resistive?

"Impedance in medicine is a characteristic of any tissue that allows current to pass through it"

How many times in Tecarterapy have we decided to use the capacitive (448kHz) or resistive (750kHz) method for the same treatment because we were not sure which to choose?

Many companies, (perhaps too many), recommend a 10 minute capacitive treatment as well as a 10 minute resistive treatment with greater pain relief.

We need to be clear about something! The electric current we are talking about goes around the body and releases more energy into areas where there are large impedance changes. More specifically, this happens at the interface of high and low impedance, where more energy is released (for example, between bones and soft tissue).

The current will always take the less difficult path (low impedance), so it will never pass through the bone, but will release energy on the outside - according to the principles indicated earlier. In assimilating this concept, it is easy to understand the difference between resistive and capacitive.

A resistive is a non-insulated metal electrode that can release energy where it encounters an impedance difference. If the electrode is below the surface, a high-impedance tissue (such as bone or a large tendon) can be identified immediately, and much of the energy is better distributed over the surface; if, on the other hand, the difference between high and low impedance is identified at greater depth, more attention must be paid to the path of the current. This current path is determined by the position between the plate and the electrode. From this it is immediately clear that resistance is necessary to work well with geometries.

Info
Article No.
UG331587
Weight
1 kg/piece
Opinions

Be the first to review this product!

Additional products